800 500 4EMC
|
|||||||||||||
|
Brea Facility
|
||
| Brea Facility Capabilities | ||||
|
|
Emissions |
Immunity |
Immunity/Emissions |
Emissions |
|
BREA OATS |
BREA BENCH |
BREA CHAMBER |
BREA OATS | |
|
RANGE LENGTH |
3-10M |
|
|
3-10M |
|
LAB DOOR DIMENSIONS |
5'W |
3'5"W |
3'W x 6'7"H |
8'W x 8'H |
|
DIAMETER OF TURNTABLE |
4'10" |
N/A |
N/A |
4' and 12' Dual |
|
WEIGHT CAPACITY OF TURNTABLE |
1 Ton |
N/A |
N/A |
1.5 Ton |
|
LAB DIMENSIONS |
Radiated Area: 11'6"L x 19'W |
15'L x 22'6"W |
9'8"L x 22'6"W |
20'L x 20'W |
|
RAMP ACCESSIBLE |
No |
No |
No |
No |
|
LOADING DOCK ACCESSIBLE |
No |
No |
No |
No |
|
EUT SUPPORT, CABLE LENGTH NEEDED |
25' |
20' |
60' | |
|
SITE CERTIFICATIONS |
A2LA to ISO 17025, FCC and VCCI |
A2LA to ISO 17025 |
A2LA to ISO 17025 |
A2LA to ISO 17025, FCC and VCCI |
|
SPECIAL OPTIONS |
|
|
Emissions pre-testing |
|
|
OTHER |
Flush mounted turn- table |
|
Fully Anechoic Room (FAR) |
Flush mounted turn- table |
|
POWER CAPABILITIES |
Single Phase. 0 to 240Vac @ 50-60Hz. | |||
1 Ton = 2,204 Lbs.
|
|
Immunity/Emissions |
Immunity/Emissions |
Emissions |
Immunity |
|
FREMONT CHAMBER 1 |
FREMONT CHAMBER 2 |
FREMONT CHAMBER 3 SITE C3 |
FREMONT BENCH 1 |
|
|
LAB DOOR DIMENSIONS |
4'W x 7'H |
7'W x 8'H |
4'W x 7'H |
5'7"W x 6'6"H |
|
DIAMETER OF TURNTABLE |
4' |
12' |
9’ |
N/A |
|
WEIGHT CAPACITY OF TURNTABLE |
1 1/2 Tons |
4 Tons |
2 Tons |
N/A |
|
LAB DIMENSIONS |
24'L x 10'W x 10'H |
32'L x 21'9"W x 10'H |
36'L x 20'W x 19.5'H |
18'10"L x 17'9"W |
|
RAMP ACCESSIBLE |
Yes |
Yes |
Yes |
No |
|
LOADING DOCK ACCESSIBLE |
Yes |
Yes |
Yes |
Yes |
|
EUT SUPPORT, CABLE LENGTH NEEDED |
25 ft. |
25 ft. |
15 ft. |
10 ft. |
|
SITE CERTIFICATIONS |
A2LA to ISO 17025 |
A2LA to ISO 17025 |
A2LA to ISO 17025 |
A2LA to ISO 17025 |
|
SPECIAL OPTIONS |
Water. Emissions pre-testing. |
Water. Emissions pre-testing. |
Water. Compressed Air. |
Water. |
|
OTHER |
Fully
Anechoic Room (FAR) |
Fully
Anechoic Room (FAR) |
Full |
Primary
bench area |
|
POWER CAPABILITIES |
Can supply only 1 set of the following instances at a time: Single
Phase OR Single
Phase OR Three Phase | |||
1
Ton = 2,204 Lbs.
1 Ton = 2,204 Lbs.
|
|
Emissions |
Immunity |
Emissions |
|
MARIPOSA BUBBLE |
MARIPOSA CHAMBER |
MARIPOSA MEADOW | |
|
RANGE
LENGTH |
10-30M |
N/A |
3-10M |
|
LAB DOOR DIMENSIONS |
7'8"W x 6'11"H and |
6'0"W x 7'3"H |
6'W x 8'H |
|
DIAMETER OF TURNTABLE |
40' |
N/A |
6'6" |
|
WEIGHT CAPACITY OF TURNTABLE |
20 Tons |
N/A |
1 Ton |
|
LAB DIMENSIONS |
45'L x 60'W |
50'L x 20'W x 12'H |
9'6"L x 11'6"W |
|
RAMP ACCESSIBLE |
Yes |
Yes |
Yes |
|
LOADING DOCK ACCESSIBLE |
Yes |
No |
No |
| EUT SUPPORT, CABLE LENGTH NEEDED |
Large Support: |
|
75' |
|
SITE CERTIFICATIONS |
A2LA to ISO 17025 |
A2LA to ISO 17025 |
A2LA to ISO 17025 |
|
SPECIAL OPTIONS |
Cooling: Chilled water @ |
A/C |
Evaporative Cooler |
|
OTHER |
Flush Mounted
Turn Table |
Semi-Anechoic
Chamber (SAC) |
Temperature
Chamber Flush Mounted
Turn Table. |
|
POWER
CAPABILITIES |
Single and 3
Phase |
Single and 3
Phase |
Single and 3
Phase |
1 Ton = 2, 204
Lbs.
|
Canyon Park Facility Capabilities Commercial
Testing | |||||
|
|
Emissions and Immunity |
Emissions |
Immunity | ||
|
CANYON
PARK CHAMBER 1 |
CANYON
PARK CHAMBER 2 |
CANYON PARK CHAMBER 3 SITE CP-3 |
CANYON
PARK BENCH 1
| ||
|
LAB DOOR DIMENSIONS |
5'1"W X
7'9"H |
5'10"W x 8'4"H |
4'W x 7'H |
6' | |
|
DIAMETER OF
TURNTABLE |
8' |
9'3" |
9' |
N/A | |
|
WEIGHT CAPACITY OF TURNTABLE |
1.5 Tons |
1.5 Tons |
2 Tons |
| |
|
LAB DIMENSIONS |
36'L x 16'Wx11'H |
28'L x 16'W x 10'H |
36'L x 20'W x 19.5'H |
12'L x 12'W x 10'H | |
|
RAMP ACCESSIBLE |
Yes |
Yes |
Yes |
N/A |
|
|
LOADING DOCK ACCESSIBLE |
Yes |
Yes |
Yes |
Yes | |
| EUT SUPPORT, CABLE LENGTH NEEDED |
18' |
18' |
15' | ||
|
SITE CERTIFICATIONS |
A2LA ISO 17025 |
A2LA ISO 17025 |
A2LA to ISO Guide 17025 |
A2LA ISO 17025 | |
|
SPECIAL
OPTIONS |
Converts to
MIL-STD Room. Emissions pre-testing |
Converts to
MIL-STD Room.
Emissions pre-testing |
Water. Compressed Air. |
| |
|
OTHER |
Fully-Anechoic Room (FAR) |
Fully-Anechoic Room (FAR) |
Full-Scan Height, 5m Emissions Chamber. |
| |
|
POWER
CAPABILITIES |
Single
Phase Three Phase AC Power Supply DC Power Supply | ||||
1 Ton = 2,204
Lbs.
|
|
Immunity/Emissions |
Support Room |
Immunity/Emissions |
Support Room |
|
CANYON PARK MIL CHAMBER 1 |
CANYON PARK MIL CHAMBER 2 |
CANYON PARK MIL CHAMBER 3 SITE M3 (CP-M2) |
CANYON PARK MIL CHAMBER 4 |
|
|
LAB DOOR DIMENSIONS |
6' x 7' |
3' x 7 ' |
3’ x 7 ’ |
3’ x 7 ’ |
|
TEST TABLE SIZE |
21'8"L x 4’ W |
2 ea. 8' L x 3' 6" W |
2 ea. 11' 8" L x 4' W |
2 ea. 8' L x 3' 6" W |
|
LAB DIMENSIONS |
17' L x 24' W x 10' H |
17' L x 17' W x 10' H |
17' L x 14' W x 10' H |
17' L x 10' W x 10' H |
|
RAMP ACCESSIBLE |
Yes |
Yes |
Yes |
Yes |
|
LOADING DOCK ACCESSIBLE |
Yes |
Yes |
Yes |
Yes |
|
|
20' |
20' |
20' |
20' |
|
SITE CERTIFICATIONS |
A2LA to ISO 17025 |
A2LA to ISO 17025 |
A2LA to ISO 17025 |
A2LA to ISO 17025 |
|
|
Water, Compressed Air |
Water, Compressed Air |
Water, Compressed Air |
Water, Compressed Air |
|
|
Semi-anechoic room. Radiated susceptibility 200 V/m up to 40 GHz. External generator power optional. |
RF shielded room. External generator power optional |
Semi-anechoic room. Radiated susceptibility 200 V/m up to 40 GHz. External generator power optional. |
RF shielded room. External generator power optional |
|
POWER CAPABILITIES |
Single
Phase Three
Phase AC Power Supply DC Power Supply | |||
1 Ton = 2,204
Lbs.