Laboratory Capabilities
 
800 500 4EMC 


Laboratory Capabilities by Location

 

Brea Facility
Fremont Facility
Fremont MIL-Aerospace Facility
Mariposa Facility  
Canyon Park Facility
Canyon Park MIL-Aerospace Facility

Brea Facility Capabilities

 

Emissions

Immunity

Immunity/Emissions

Emissions

BREA OATS
SITE A

BREA BENCH
SITE B

BREA CHAMBER
SITE C

BREA OATS
SITE D

RANGE LENGTH

3-10M

-

-

3-10M

LAB DOOR DIMENSIONS

5'W

3'5"W

3'W x 6'7"H

8'W x 8'H

DIAMETER OF TURNTABLE

4'10"

N/A

N/A

4' and 12' Dual

WEIGHT CAPACITY OF TURNTABLE

1 Ton

N/A

N/A

1.5 Ton

LAB DIMENSIONS

Radiated Area: 11'6"L x 19'W
Conducted Area: 8'6"L x 10'10"W

15'L x 22'6"W

9'8"L x 22'6"W

20'L x 20'W

RAMP ACCESSIBLE

No

No

No

No

LOADING DOCK ACCESSIBLE

No

No

No

No

EUT SUPPORT, CABLE LENGTH NEEDED

25'

20'

60'

SITE CERTIFICATIONS

A2LA to ISO 17025, FCC and VCCI

A2LA to ISO 17025

A2LA to ISO 17025

A2LA to ISO 17025, FCC and VCCI

SPECIAL OPTIONS

-

-

Emissions pre-testing

-

OTHER

Flush mounted turn- table

-

 Fully Anechoic Room (FAR)

Flush mounted turn- table

POWER CAPABILITIES

Single Phase.

0 to 240Vac @ 50-60Hz.
14 Amp Maximum

1 Ton = 2,204 Lbs.

Top 


 

Fremont Facility Capabilities

-

Immunity/Emissions

Immunity/Emissions

Emissions

Immunity

FREMONT CHAMBER 1
SITE C1

FREMONT CHAMBER 2
SITE C2

FREMONT CHAMBER 3
SITE C3

FREMONT BENCH 1
SITE B1

LAB DOOR DIMENSIONS

4'W x 7'H

7'W x 8'H

4'W x 7'H

5'7"W x 6'6"H

DIAMETER OF TURNTABLE

4'

12'

9

N/A

WEIGHT CAPACITY OF TURNTABLE

1 1/2 Tons

4 Tons

2 Tons

N/A

LAB DIMENSIONS

24'L x 10'W x 10'H

32'L x 21'9"W x 10'H

36'L x 20'W x 19.5'H

18'10"L x 17'9"W

RAMP ACCESSIBLE

Yes

Yes

Yes

No

LOADING DOCK ACCESSIBLE

Yes

Yes

Yes

Yes

EUT SUPPORT, CABLE LENGTH NEEDED

25 ft.

25 ft.

15 ft.

10 ft.

SITE CERTIFICATIONS

A2LA to ISO 17025

A2LA to ISO 17025

A2LA to ISO 17025

A2LA to ISO 17025

SPECIAL OPTIONS

Water.  Emissions pre-testing.

Water.  Emissions pre-testing.

Water.  Compressed Air.

Water.

OTHER

Fully Anechoic Room (FAR)

Fully Anechoic Room (FAR)

Full-Scan Height, 5 m Emissions Chamber.

Primary bench area

POWER CAPABILITIES

Can supply only 1 set of the following instances at a time:

Single Phase
120 to 208Vac @ 60Hz; 30 Amp Max.
208Vac @ 60Hz; 30 Amp Max.
Pacific Power Supply:

OR

Single Phase
A. 120Vac @ 50-60Hz; 25 Amp Max.
B. 230-240Vac @ 50-60Hz; 12 Amp Max.

OR

Three Phase
C. 260 Vac @ 50-60Hz; 12 Amp Max.
D. Over 260Vac @ 50-60 Hz; 6 Amp Max.
E. Over 480Vac, see Christine.

 1 Ton = 2,204 Lbs.

Top 

 

Fremont Capabilities
Military and Aerospace Testing

 

Immunity/Emissions

Immunity/Emissions

FREMONT MIL CHAMBER
SITE MIL (F-M)

FREMONT CHAMBER 2
SITE C2

LAB DOOR DIMENSIONS

3' x 7' 6"

6' 3" x 8' 2"

TEST TABLE SIZE

  12' L x 3' 3" W

3 ea. 15' L x 3' 6" W

LAB DIMENSIONS

  18'.6"W x 18'6"L x 13'H

32'L x 21'9"W x 10'H

RAMP ACCESSIBLE

Yes

Yes

LOADING DOCK ACCESSIBLE

Yes

Yes

EUT SUPPORT, CABLE LENGTH NEEDED

20'

25'

SITE CERTIFICATIONS

A2LA to ISO 17025

 A2LA to ISO 17025

SPECIAL OPTIONS

Water, Compressed Air

 Water, Compressed Air

OTHER

Semi-anechoic room with attached 8'W x 18'6"L x 13'H shielded ante room. Radiated susceptibility 200 V/m up to 40GHz. External generator power optional.

Semi-anechoic room. Radiated susceptibility 200 V/m up to 40GHz. External generator power optional.

POWER CAPABILITIES

Single Phase
120V ac @ 60Hz; 20 Amp Max.
208Vac @ 60Hz; 30 Amp Max.
230Vac @ 50Hz; 15 Amp Max.

Three Phase
208Vac @ 60Hz; 30 Amp Max.

AC Power Supply
0-300Vac @ 45-5000Hz; 15 Amp Max.

DC Power Supply
0-100Vdc; 2000 Watts Max.

1 Ton = 2,204 Lbs.

Top

 

Mariposa Facility Capabilities

-

Emissions

Immunity

Emissions

MARIPOSA BUBBLE
SITE A

MARIPOSA CHAMBER
SITE C

MARIPOSA MEADOW
SITE D

RANGE LENGTH

10-30M

N/A

3-10M

LAB DOOR DIMENSIONS

7'8"W x 6'11"H and
10'W x 10'H

6'0"W x 7'3"H

6'W x 8'H

DIAMETER OF TURNTABLE

40'

N/A

6'6"

WEIGHT CAPACITY OF TURNTABLE

20 Tons

N/A

1 Ton

LAB DIMENSIONS

45'L x 60'W

50'L x 20'W x 12'H

9'6"L x 11'6"W

RAMP ACCESSIBLE

Yes

Yes

Yes

LOADING DOCK ACCESSIBLE

Yes

No

No

EUT SUPPORT, CABLE LENGTH NEEDED

Large Support:
70' (radiated),
90' (conducted)

Small Support:
10' (under table)

35'

75'

SITE CERTIFICATIONS

A2LA to ISO 17025
VCCI and FCC

A2LA to ISO 17025

A2LA to ISO 17025
VCCI and FCC

SPECIAL OPTIONS

Cooling: Chilled water @
30 GPM and A/C.
Air: 80 PSI w/ oil and water separator

A/C

Evaporative Cooler

OTHER

Flush Mounted Turn Table

Semi-Anechoic Chamber (SAC)

Temperature Chamber
16W x 10.75W x 12.5H

Flush Mounted Turn Table.

POWER CAPABILITIES

Single and 3 Phase
50 to 480 Vac @ 60Hz;
50 to 460Vac @ 50Hz.
200 Amp Maximum.

Single and 3 Phase
110/240Vac @ 60Hz.
30 Amp Maximum.

Single and 3 Phase
50 to 480Vac @ 60Hz;
50 to 460Vac @ 50Hz.30 Amp Maximum.

1 Ton = 2, 204 Lbs.

Top


 

Canyon Park Facility Capabilities

Commercial Testing

-

Emissions and Immunity

Emissions

Immunity

CANYON PARK CHAMBER 1
SITE C1

CANYON PARK CHAMBER 2
SITE C2

CANYON PARK CHAMBER 3 SITE CP-3

CANYON PARK BENCH 1
SITE B1

CANYON PARK BENCH 2
SITE B2

LAB DOOR DIMENSIONS

5'1"W X 7'9"H

5'10"W x 8'4"H

4'W x 7'H

6' x 8'

DIAMETER OF TURNTABLE

8'

9'3"

9'

N/A

WEIGHT CAPACITY OF TURNTABLE

1.5 Tons

1.5 Tons

2 Tons

N/A

LAB DIMENSIONS

36'L x 16'Wx11'H

28'L x 16'W x 10'H

36'L x 20'W x 19.5'H

12'L x 12'W x 10'H

RAMP ACCESSIBLE

Yes

Yes

Yes

N/A

LOADING DOCK ACCESSIBLE

Yes

Yes

Yes

Yes

EUT SUPPORT, CABLE LENGTH NEEDED

18'

18'

15'

SITE CERTIFICATIONS

A2LA ISO 17025

A2LA ISO 17025

A2LA to ISO Guide 17025

A2LA ISO 17025

SPECIAL OPTIONS

Converts to MIL-STD Room. Emissions pre-testing

Converts to MIL-STD Room.  Emissions pre-testing

Water. Compressed Air.

-

OTHER

 Fully-Anechoic Room (FAR)

 Fully-Anechoic Room (FAR)

Full-Scan Height, 5m Emissions Chamber.

-

POWER CAPABILITIES

Single Phase
120Vac @ 60Hz; 20 Amp Max.
208Vac @ 60Hz; 30 Amp Max.
230Vac @ 50Hz; 15 Amp Max.

Three Phase
208Vac @ 60Hz; 30 Amp Max.

AC Power Supply
0-300Vac @ 45-5000Hz; 15 Amp Max.

DC Power Supply
0-100VDC; 2000 Watts Max.

1 Ton = 2,204 Lbs.

Top


 

Canyon Park Capabilities
Military and Aerospace Testing

-

Immunity/Emissions

Support Room

Immunity/Emissions

Support Room

CANYON PARK MIL CHAMBER 1
SITE M1 (CP-M1)

CANYON PARK MIL CHAMBER 2
SITE M2 (CP-M2)

CANYON PARK MIL CHAMBER 3
SITE M3 (CP-M2)

CANYON PARK MIL CHAMBER 4
SITE M4(CP-M2)

LAB DOOR DIMENSIONS

6' x 7'

3' x 7 '

3’ x 7 ’

3’ x 7 ’

TEST TABLE SIZE

21'8"L x 4’ W

2 ea. 8' L x 3' 6" W
2 ea. 12' L x 3' 6" W

2 ea. 11' 8" L x 4' W

2 ea. 8' L x 3' 6" W

LAB DIMENSIONS

17' L x 24' W x 10' H

17' L x 17' W x 10' H

17' L x 14' W x 10' H

17' L x 10' W x 10' H

RAMP ACCESSIBLE

Yes

Yes

Yes

Yes

LOADING DOCK ACCESSIBLE

Yes

Yes

Yes

Yes

EUT SUPPORT, CABLE LENGTH NEEDED

20'

20'

20'

20'

SITE CERTIFICATIONS

A2LA to ISO 17025

A2LA to ISO 17025

A2LA to ISO 17025

A2LA to ISO 17025

SPECIAL OPTIONS

Water, Compressed Air

Water, Compressed Air

Water, Compressed Air

Water, Compressed Air

OTHER

Semi-anechoic room. Radiated susceptibility 200 V/m up to 40 GHz. External generator power optional.

RF shielded room. External generator power optional

Semi-anechoic room. Radiated susceptibility 200 V/m up to 40 GHz. External generator power optional.

RF shielded room. External generator power optional

POWER CAPABILITIES

Single Phase
120V ac @ 60Hz; 20 Amp Max.
208Vac @ 60Hz; 30 Amp Max.
230Vac @ 50Hz; 15 Amp Max.

Three Phase
208Vac @ 60Hz; 30 Amp Max.

AC Power Supply
0-300Vac @ 45-5000Hz; 15 Amp Max.

DC Power Supply
0-100Vdc; 2000 Watts Max.

1 Ton = 2,204 Lbs. 

Top


 